A
Troubleshooting
A-34
6.238 : Too many point data
Code
: &H0006 &H00EE
Meaning/Cause
More than 32 values of point data are specified for movement command.
Action
Specify 32 or less values of point data for one movement command line.
6.239 : Illegal PATH task no
Code
: &H0006 &H00EF
Meaning/Cause
The "PATH L", "PATH C", or "PATH END" command was executed in different task from that
executed the "PATH SET" command.
Action
Execute commands from the "PATH SET" to the "PATH END" in the same task.
6.251 : Stack underflow
Code
: &H0006 &H00FB
Meaning/Cause
a. The "RESUME" statement was executed outside the alarm routine.
b. Error occurred in software.
Action
a. Use the "RESUME" statement within the alarm routine declared in "ON ERROR GOTO".
b. Contact your distributor.
6.252 : Data out of range
Code
: &H0006 &H00FC
Meaning/Cause
The specified value is out of the input range.
Action
Specify the value within the input range.
6.253 : Illegal point no
Code
: &H0006 &H00FD
Meaning/Cause
The specified point number is out of the range; between 0 and 29999.
Action
Specify a point number between 0 and 29999.
6.254 : Illegal shift no
Code
: &H0006 &H00FE
Meaning/Cause
The specified shift number is out of the range; between 0 and 39.
Action
Specify a shift number between 0 and 39.
6.255 : Illegal hand no
Code
: &H0006 &H00FF
Meaning/Cause
The specified hand number is out of the range; between 0 and 31.
Action
Specify a hand number between 0 and 31.
6.256 : Illegal pallet no
Code
: &H0006 &H0100
Meaning/Cause
The specified pallet number is out of the range; between 0 and 39.
Action
Specify a pallet number between 0 and 39.
Summary of Contents for YRCX Series
Page 1: ...7 6HULHV DW 1R 1 5 5RERW RQWUROOHU 23 5 7 21 0 18 6 5 5RERWV 5 6HULHV...
Page 2: ......
Page 10: ......
Page 12: ......
Page 14: ......
Page 20: ......
Page 28: ......
Page 164: ......
Page 166: ......
Page 178: ......
Page 186: ......
Page 264: ......
Page 265: ......
Page 266: ...DW 1R 1 XWKRUL HG LVWULEXWRU 3ULQWHG LQ XURSH...