A
Troubleshooting
A-38
6.312 : ABS. reset position incomplete
Code
: &H0006 &H0138
Meaning/Cause
Absolute reset was executed at a position where the absolute reset cannot be performed.
Action
Move to a position where the absolute reset can be performed.
6.313 : MRK. motor disconnected
Code
: &H0006 &H0139
Meaning/Cause
Return-to-origin was executed without mark-specified axes.
Action
Check the system generation data.
6.314 : Can't execute while servo on
Code
: &H0006 &H013A
Meaning/Cause
Writing in "ALL" or "PRM" files was attempted in servo on status.
Action
Turn off the servo before writing files.
6.315 : ZR torque origin incorrect setting
Code
: &H0006 &H013B
Meaning/Cause
a. Simultaneous return-to-origin was performed while the ZR-stroke end method was set.
b. R-axis stack was not set for the Z-axis.
c. Either Z or R-axis return-to-origin method was not set to the ZR-stroke end method.
d. Multiple Z-axis (or R-axis) return-to-origin methods were set to the ZR-stroke end method.
Action
a. Set the return-to-origin order correctly. (Simultaneous return-to-origin cannot be performed.)
b. Set the R-axis stack correctly.
c. Set both Z and R-axis return-to-origin methods to the ZR-stroke end method.
d. Set Z and R-axis one each for the ZR-stroke end method.
6.316 : Can't execute while motor power on
Code
: &H0006 &H013C
Meaning/Cause
The parameter that cannot be written in motor power off status was saved.
Action
Turn off the motor, and then save the parameter.
6.317 : Illegal origin method
Code
: &H0006 &H013D
Meaning/Cause
a. Performing return-to-origin (mark method) was attempted.
b. Only one of Z or R-axis is set to ZR-stroke end method.
Action
a. Perform absolute reset for axes of “Mark" method using the programming box or support software.
b. Set both Z and R-axis at "ZR-stroke end method".
6.319 : Can't change hand data
Code
: &H0006 &H013F
Meaning/Cause
a. Changing the hand setting that another robot is using was attempted.
b. Specifying the hand R for the robot without R-axis was attempted.
Action
a. Release the hand setting of the other robot.
b. Set blank for the fourth parameter of the target parameter.
6.321 : Illegal option slot no
Code
: &H0006 &H0141
Meaning/Cause
The specified option slot number is out of the range; between 1 and 4.
Action
Specify an option slot number between 1 and 4.
Summary of Contents for YRCX Series
Page 1: ...7 6HULHV DW 1R 1 5 5RERW RQWUROOHU 23 5 7 21 0 18 6 5 5RERWV 5 6HULHV...
Page 2: ......
Page 10: ......
Page 12: ......
Page 14: ......
Page 20: ......
Page 28: ......
Page 164: ......
Page 166: ......
Page 178: ......
Page 186: ......
Page 264: ......
Page 265: ......
Page 266: ...DW 1R 1 XWKRUL HG LVWULEXWRU 3ULQWHG LQ XURSH...