DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
591
DWS-3160-24PC:admin#config sflow flow_sampler ports 1 rate 0 maxheadersize 18
Command: config sflow flow_sampler ports 1 rate 0 maxheadersize 18
Success.
DWS-3160-24PC:admin#
64-3
delete sflow flow_sampler
Description
This command is used to delete the sFlow flow sampler.
Format
delete sflow flow_sampler ports [<portlist> | all]
Parameters
ports
- Specifies the list of ports to be configured.
<portlist>
- Enter the list of ports that will be used for this configuration here.
all
- Specifies all ports on the Switch.
Restrictions
Only Administrators and Operators can issue this command.
Example
To delete the sFlow sampler port 1:
DWS-3160-24PC:admin# delete sflow flow_sampler ports 1
Command: delete sflow flow_sampler ports 1
Success.
DWS-3160-24PC:admin#
64-4
create sflow counter_poller
Description
This command is used to create the sFlow counter poller. The poller function instructs the Switch
to forward statistics counter information with respect to a port.
Format
create sflow counter_poller ports [<portlist> | all] analyzer_server_id <value 1-4> {interval
[disable | <sec 20-120>]}