Device Framework Tests
| 121 of 124
S
u
pe
rS
pe
ed
U
S
B
Ex
pl
o
re
r
2
8
0
Test Steps and Expected Results
1.
Examiner initializes link to U0.
2.
Examiner issues several standard descriptor requests.
3.
Examiner issues a request for the Configuration Descriptor.
The Configuration Descriptor must be at least 9 bytes in length.
4.
Examiner issues a Set Configuration (1) followed by a Get Configuration request.
The device must indicate a change to configuration 1.
5.
Examiner issues a request for the Configuration Descriptor.
The Configuration Descriptor must be at least 9 bytes in length.
6.
Examiner issues a Set Configuration (1) followed by a Get Configuration request.
The device must indicate a change to configuration 1.
7.
Examiner issues a Set Configuration (0) followed by a Get Configuration request.
The device must indicate a change to configuration 0.
8.
Examiner issues a Set Configuration (1) followed by a Get Configuration request.
The device must indicate a change to configuration 1.
Specification Reference
USB Command Verifier Compliance Test Specification TD9.13.