92 of 124 |
Mass Storage Class Tests
Ex
ami
n
er
U
se
r
G
u
ide
3.
Examiner issues a Read Capacity command with an incorrect signature in the command
block word.
Device must complete the command transport.
4.
Examiner sends a series of IN and OUT requests, then sends a Get Status to the IN
endpoint.
Device must stall the IN requests and respond as halted to the Get Status
request.
Device must stall or complete the OUT requests.
5.
Examiner sends Clear Feature and Get Status requests to the IN and OUT endpoints.
Device IN and OUT endpoint must not be halted.
6.
Examiner sends a mass storage command with a CBW truncated to 30 bytes.
Device must complete the command transport.
7.
Examiner sends a series of IN requests.
Device must stall the IN requests
8.
Examiner sends Clear Feature and Get Status requests to the IN and OUT endpoints.
Device IN and OUT endpoint must not be halted.
9.
Examiner sends a mass storage command with a CBW padded to 32 bytes.
Device must complete the command transport.
10.
Examiner sends a series of IN transactions.
Device must stall the IN requests.
11.
Examiner sends Clear Feature requests to the IN and OUT endpoints.
Device IN and OUT endpoint must not be halted.