VOLTage Subsystem
Command/Query
Description
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude] <
value
>|MINimum|MAXimum[,
<
low_limit
>|MINimum|MAXimum, <
high_limit
>|MINimum|MAXimum]
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Sets the immediate AC voltage level, and
optionally the soft limits.
[SOURce:]VOLTage[:LEVel]:LIMit[:STATe] ON|1|OFF|0
[SOURce:]VOLTage[:LEVel]:LIMit[:STATe]?
Enables or disables soft limits for AC
voltage.
[SOURce:]VOLTage[:LEVel]:LIMit:LOWer <
value
>|MINimum|MAXimum
[SOURce:]VOLTage[:LEVel]:LIMit:LOWer? [MINimum|MAXimum]
Sets the lower and upper AC voltage limits.
[SOURce:]VOLTage[:LEVel]:LIMit:UPPer <
value
>|MINimum|MAXimum
[SOURce:]VOLTage[:LEVel]:LIMit:UPPer? [MINimum|MAXimum]
[SOURce:]VOLTage[:LEVel]:MODE FIXed|STEP
[SOURce:]VOLTage[:LEVel]:MODE?
Sets the trigger transient mode for voltage
settings.
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude] <
value
>|MINimum|MAXimum
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]? [MINimum|MAXimum]
Sets the triggered AC voltage level.
[SOURce:]VOLTage:OFFSet[:IMMediate] <
value
>|MINimum|MAXimum [,<
low_
limit
>|MINimum|MAXimum,<
high_limit
>|MINimum|MAXimum]
[SOURce:]VOLTage:OFFSet[:IMMediate]? [MINimum|MAXimum]
Sets the immediate DC voltage in VDC, and
also optionally sets the soft limits.
[SOURce:]VOLTage:OFFSet:LIMit[:STATe] ON|1|OFF|0
[SOURce:]VOLTage:OFFSet:LIMit[:STATe]?
Enables or disables soft limits for DC
voltage.
[SOURce:]VOLTage:OFFSet:LIMit:LOWer <
value
>|MINimum|MAXimum
[SOURce:]VOLTage:OFFSet:LIMit:LOWer? [MINimum|MAXimum]
[SOURce:]VOLTage:OFFSet:LIMit:UPPer <
value
>|MINimum|MAXimum
[SOURce:]VOLTage:OFFSet:LIMit:UPPer? [MINimum|MAXimum]
Sets the lower and upper DC voltage soft
limits.
[SOURce:]VOLTage:OFFSet:MODE FIXed|STEP
[SOURce:]VOLTage:OFFSet:MODE?
Sets the trigger transient mode for DC
voltage settings.
[SOURce:]VOLTage:OFFSet:TRIGgered <
value
>|MINimum|MAXimum
[SOURce:]VOLTage:OFFSet:TRIGgered? [MINimum|MAXimum]
Sets the triggered DC voltage in VDC.
[SOURce:]VOLTage:PROGramming:SOURce INTernal|EXTAC|EXTDC
[SOURce:]VOLTage:PROGramming:SOURce?
Sets the voltage programming source.
[SOURce:]VOLTage:RANGe[:UPPer] 155|310|MINimum|MAXimum
[SOURce:]VOLTage:RANGe[:UPPer]? [MINimum|MAXimum]
Sets the voltage range.
[SOURce:]VOLTage:RANGe:AUTO ON|1|OFF|0
[SOURce:]VOLTage:RANGe:AUTO?
Enables or disables voltage autoranging.
3 SCPI Programming Reference
114
Keysight AC6800B Series Operating and Service Guide
Summary of Contents for AC6801B
Page 1: ...Operating and Service Guide Keysight AC6800B Series Basic AC Sources...
Page 16: ...AC6802B 1 Getting Started 16 Keysight AC6800B Series Operating and Service Guide...
Page 17: ...AC6803B Keysight AC6800B Series Operating and Service Guide 17 1 Getting Started...
Page 18: ...AC6804B 1 Getting Started 18 Keysight AC6800B Series Operating and Service Guide...
Page 62: ......
Page 196: ...4 Calibration Verification and Service 196 Keysight AC6800B Series Operating and Service Guide...