smDbSyncInterval
Set/display how often a Master SM should perform a full sync with standby SMs.
Syntax:
Options:
Sample Output:
NOTES:
Value must be between 0 and 60 minutes (0=OFF).
smDynamicPlt
Set/display dynamic packet lifetime values.
Syntax:
Options:
smDbSyncInterval [minutes]
None.
-> smDbSyncInterval 15
Set db sync interval to 15 minutes
-> smDbSyncInterval
SM DB full sync interval currently set to 15 minutes
-----SM DB SYNCHRONIZATION interval set to 900 seconds, 2 SM(s) in
fabric-----
MASTER SM node at SilverStorm 9024 DDR GUID=0x00066a00d90003fa, LID
0x0008, PortGuid 0x00066a00d90003fa
Sync Capability is SUPPORTED
STANDBY SM node at st44, LID 0x0100, PortGuid 0x00066a00a0000357
Sync Capability is SUPPORTED
Full sync status is SYNCHRONIZED
Time of last Full sync is THU APR 10 15:37:47 2008
Time of last INFORM records sync is THU APR 10 15:37:47 2008
Time of last GROUP records sync is THU APR 10 15:37:47 2008
Time of last SERVICE records sync is THU APR 10 15:37:47 2008
smDynamicPlt [index] [plt]
index
The index of the entry in the table to be changed. Range is 1-9..
plt