SIGLENT
106 SSG5000X Programming Guide
3.8.4.4
Sequence ([:SOURce]:RADio:ARB:SEQuence)
Comman
d Format
[:SOURce]:RADio:ARB:SEQuence
"<file_name>","<waveform1>",<reps>,NONE|M1|M2|M3|M4|M1M2|M1M3|M1M4|
M2M3|M2M4|M3M4|M1M2M3|M1M2M4|M1M3M4|M2M3M4|ALL,{"<waveform2>",
<reps>,NONE|M1|M2|M3|M4|M1M2|M1M3|M1M4|M2M3|M2M4|M3M4|M1M2M3|M
1M2M4|M1M3M4|M2M3M4|ALL}
[:SOURce]:RADio:ARB:SEQuence? "<file_name>"
Instructio
n
This command creates a waveform sequence. A waveform sequence is made
up of segments and other sequences.
Any number of segments, up to a segment count limit of 1024, can be used to
create a sequence. The count limit is determined by the number of segments
in the waveform sequence. Repeated segments are included in the count
limit.
Paramete
r Type
String, String, Integer, Enumeration
Paramete
r Range
None, None, 1 ~ 65536, NONE|M1|M2|M3|M4|M1M2|M1M3|M1M4|M2M3|
M2M4|M3M4|M1M2M3|M1M2M4|M1M3M4|M2M3M4|M1M2M3M4
Return
String
Default
None
Menu
ARB > Waveform Sequence > Build
Example
:RADio:ARB:SEQuence “TEST_SEQ”,”RENAME_WAVE”,1,M1
3.8.4.5
Modulator Atten Type
([:SOURce]:RADio:ARB:IQ:MODulation:ATTen:AUTO)
Command
Format
[:SOURce]:RADio:ARB:IQ:MODulation:ATTen:AUTO AUTO|MANUal
[:SOURce]:RADio:ARB:IQ:MODulation:ATTen:AUTO?
Instruction
This command enables or disables the I/Q attenuation auto mode
Parameter
Type
Enumeration
Parameter
Range
AUTO|MANUal
Return
Enumeration