SIGLENT
SSG5000X Programming Guide 99
function
Parameter
Type
Boolean
Parameter
Range
ON|OFF|1|0
Return
Boolean
Default
0
Menu
Multitone > Multitone State
Example
:RADio:MTONe:ARB 1
3.8.2.2
Tone Number
([:SOURce]:RADio:MTONe:ARB:SETup:TABLe:NTONes)
Command
Format
[:SOURce]:RADio:MTONe:ARB:SETup:TABLe:NTONes <num_tones>
[:SOURce]:RADio:MTONe:ARB:SETup:TABLe:NTONes?
Instruction
This command defines the number of tones in the multitone waveform
Parameter
Type
Integer
Parameter
Range
1 ~ 20
Return
Integer
Default
2
Menu
Multitone > Tone Number
Example
:RADio:MTONe:ARB:SETup:TABLe:NTONes 1
3.8.2.3
Single Side
([:SOURce]:RADio:MTONe:ARB:SETup:TABLe:SINGle)
Command
Format
[:SOURce]:RADio:MTONe:ARB:SETup:TABLe:SINGle ON|OFF|1|0
[:SOURce]:RADio:MTONe:ARB:SETup:TABLe:SINGle?
Instruction
This command enables or disables the multitone single side
Parameter
Type
Boolean
Parameter
Range
ON|OFF|1|0