SIGLENT
SSG5000X Programming Guide 65
Default
0
Menu
PULSE > Pulse Out
Example
PULM:OUT ON
3.6.8.3
Pulse Source ([:SOURce]:PULM:SOURce)
Command
Format
[:SOURce]:PULM:SOURce
INTernal|EXTernal
[:SOURce]:PULM:SOURce
?
Instruction
Select the source for the pulse modulation signal
Get the source for the pulse modulation signal
Parameter
Type
Enumeration
Parameter
Range
INTernal|EXTernal
Return
Enumeration
Default
INTernal
Menu
PULSE > Pulse Source
Example
PULM:SOUR
INTernal
3.6.8.4
Pulse Polarity ([:SOURce]:PULM:POLarity)
Command
Format
[:SOURce]:PULM:POLarity
NORMal|INVerted
[:SOURce]:PULM:POLarity
?
Instruction
Set the period of the generated pulse. The period determines the repetition
frequency of the internal signal
Get the period of the generated pulse
Parameter
Type
Enumeration
Parameter
Range
NORMal|INVerted
Return
Enumeration
Default
NORMal
Menu
PULSE > Pulse Polarity
Example
PULM:POL INV