SIGLENT
108 SSG5000X Programming Guide
3.8.4.8
Output Mux ([:SOURce]:RADio:ARB:NOISe:OUTPut)
Command
Format
[:SOURce]:RADio:ARB:NOISe:OUTPut CARRier|NOISe|CARRier_NOISe
[:SOURce]:RADio:ARB:NOISe:OUTPut?
Instruction
This command selects output type of the Real Time AWGN.
Parameter
Type
Enumeration
Parameter
Range
CARRier|NOISe|CARRier_NOISe
Return
Enumeration
Default
CARRier_NOISe
Menu
ARB > ARB Setup > Real Time AWGN > Output Mux
Example
:RADio:ARB:NOISe:OUTPut CARRier
3.8.4.9
Power Control
([:SOURce]:RADio:ARB:NOISe:POWer:TYPE)
Command
Format
[:SOURce]:RADio:ARB:NOISe:POWer:TYPE CARRier|CHNO|TONO|TOPO
[:SOURce]:RADio:ARB:NOISe:POWer:TYPE?
Instruction
This command selects the power control mode of the Real Time AWGN.
Parameter
Type
Enumeration
Parameter
Range
CARRier|CHNO|TONO|TOPO
Return
Enumeration
Default
TOPO
Menu
ARB > ARB Setup > Real Time AWGN > Power Control Mode
Example
:RADio:ARB:NOISe:POWer:TYPE CARRier
3.8.4.10
Total Power
([:SOURce]:RADio:ARB:NOISe:POWer:TOTAl)
Command
Format
[:SOURce]:RADio:ARB:NOISe:POWer:TOTAl <power>
[:SOURce]:RADio:ARB:NOISe:POWer:TOTAl?
Instruction
This command sets the total power of the Real Time AWGN.