SIGLENT
SSG5000X Programming Guide 45
Range
Return
Float, unit: dB
Default
0 dB
Menu
SENSOR > Level Control > Catch Range
Example
:POWer:SPC:CRANge 5
3.6.3
[:SOURce]:SWEep Subsystem
3.6.3.1
Sweep State ([:SOURce]:SWEep:STATe)
Command
Format
[:SOURce]:SWEep:STATe
OFF|FREQuency|LEVel|LEV_FREQ
[:SOURce]:SWEep:STATe
?
Instruction
Activate frequency or/and level sweep
Parameter
Type
Enumeration
Parameter
Range
OFF|FREQuency|LEVel|LEV_FREQ
Return
Enumeration
Default
OFF
Menu
SWEEP > Sweep State
Example
:SWEep:STATe OFF
3.6.3.2
Sweep Type ([:SOURce]:SWEep:TYPE)
Command
Format
[:SOURce]:SWEep:TYPE
LIST|STEP
[:SOURce]:SWEep:TYPE
?
Instruction
Set sweep type
Get sweep type
Parameter
Type
Enumeration
Parameter
Range
LIST|STEP
Return
Enumeration
Default
STEP
Menu
SWEEP > Step Sweep / List Sweep
Example
:SWEep:TYPE STEP