SIGLENT
SSG5000X Programming Guide 71
Menu
PULSE > Pulse Train > Load
Example
PULM:TRAin:LOAD test.pulstrn
3.6.8.17
Pulse Train Store ([:SOURce]:PULM:TRAin:STORE)
Command
Format
[:SOURce]:PULM:TRAin:STORE <file>
Instruction
Store train pair list
Parameter
Type
String
Parameter
Range
None
Return
None
Default
None
Menu
PULSE > Pulse Train
Example
PULM:TRAin:STORE test.pulstrn
3.6.8.18
Trigger Out ([:SOURce]:PULM:TRIGger:STATe)
Command
Format
[:SOURce]:PULM:TRIGger:STATe
ON|OFF|1|0
[:SOURce]:PULM:TRIGger:STATe
?
Instruction
Set the trigger output status
Get the trigger output status
Parameter
Type
Boolean
Parameter
Range
ON|OFF|1|0
Return
Boolean
Default
1
Menu
PULSE > Trigger Out
Example
PULM:TRIGger:STATe
ON
3.6.8.19
Pulse Trigger ([:SOURce]:PULM:TRIGger:MODE)
Command
Format
[:SOURce]:PULM:TRIGger:MODE
AUTO|KEY|EXTernal|EGATe
[:SOURce]:PULM:TRIGger:MODE
?