2-13
threshold
-
value2
: Lower threshold, in the range 0 to 2147483647.
event
-
entry2
: Index of the event entry that corresponds to the falling threshold, in the range 0 to 65535.
forever
: Specifies the corresponding RMON alarm instance is valid permanently.
cycle
: Specifies the corresponding RMON alarm instance is valid periodically.
cycle
-
period
: Life time (in seconds) of the RMON alarm instance, in the range 0 to 2147483647.
owner text
: Specifies the owner of the alarm entry, a string of 1 to 127 characters.
Description
Use the
rmon prialarm
command to create an extended entry in an extended RMON alarm table. If you
do not specify the
owner text
keyword/argument combination, the owner of the entry is displayed as
“null”.
Use the
undo rmon prialarm
command to remove an extended alarm entry.
z
Before adding an extended alarm entry, you need to use the
rmon event
command to define the
events to be referenced by the entry.
z
Make sure the node to be monitored exists before executing the
rmon event
command.
z
You can define up to 50 extended alarm entries.
With an extended alarm entry defined in an extended alarm group, the device performs the following
operations accordingly:
z
Sampling the alarm variables referenced in the defined extended alarm expression
(
prialarm-formula
) once in each period specified by the
sampling-timer
argument.
z
Performing operations on the sampled values according to the defined extended alarm expression
(
prialarm-formula
)
z
Comparing the operation result with the set thresholds and perform corresponding operations, as
described in
Table 2-8
.
Table 2-8
Operation result and corresponding operation
Comparison
Operation
The operation result is larger than or equal to the
set upper threshold (
threshold-value1
)
Triggering the event identified by the
event-entry1
argument
The operation result is smaller than or equal to
the set lower threshold (
threshold-value2
)
Triggering the event identified by the
event-entry2
argument
Examples
# Add the extended alarm entry numbered 2 as follows:
z
Perform operations on the corresponding alarm variables using the expression
((1.3.6.1.2.1.16.1.1.1.4.1)*100).
z
Sampling interval: 10 seconds
z
Rising threshold: 50
Summary of Contents for 5500-EI PWR
Page 43: ...2 6...
Page 76: ...1 17...
Page 228: ...ii stp transmit limit 1 44 vlan mapping modulo 1 45 vlan vpn tunnel 1 46...
Page 477: ...5 24 Sysname vlan 2 Sysname vlan2 service type multicast...
Page 503: ...2 3 System View return to User View with Ctrl Z Sysname dot1x url http 192 168 19 23...
Page 519: ...iii...
Page 597: ...2 2 security policy server 192 168 0 1 user name format without domain...
Page 648: ...1 9 Examples Clear static ARP entries Sysname reset arp static...
Page 663: ...4 3 Sysname resilient arp interface vlan interface 2...
Page 767: ...1 28 From 12 00 Jan 1 2008 to 12 00 Jun 1 2008...
Page 1111: ...ii xmodem get 3 18...
Page 1314: ...A 44 Z...