Fabric OS Reference
1-139
Telnet Commands
1
parityCheck
Enable or disable DRAM parity checking.
Synopsis
parityCheck [0|1]
Availability
admin
Description
This command enables DRAM parity checking. The mode is saved in flash memory and stays in
that mode until the next execution of parityCheck.
The mode becomes active as soon as this command is executed. It does not require a reboot to take
effect.
The DRAM parity checking, when enabled causes ramTest to perform several additional tests of
the parity memory. It also enables the parity checking hardware to verify proper parity on all
DRAM read operations. DRAM parity checking is only available on specific switch models. If the
current switch does not support parity checking an error is displayed.
Operands
This command has the following operand:
0|1
Specify a 1 to enable DRAM parity checking or specify a 0 to disable it. The
default (if no operand is specified) is to disable parity checking. This operand is
optional.
Example
To enable and disable DRAM parity checking:
See Also
ramTest
switch:admin> parityCheck 1
Committing configuration...done.
Parity check is now ON.
switch:admin> parityCheck 0
Committing configuration...done.
Parity check is now OFF.
switch:admin> parityCheck 0
Parity not supported on system model: 4
Parity check already OFF.
Summary of Contents for StorageWorks 8B - FC Entry Switch
Page 1: ...reference manual version 3 0 fabric os www hp com ...
Page 14: ...xiv Fabric OS Reference ...
Page 189: ...Fabric OS Reference 1 175 Telnet Commands 1 portCfgLongDistance portCfgTrunkport portCfgSpeed ...
Page 302: ...1 288 Fabric OS Reference Telnet Commands 1 ...
Page 342: ...Index 4 Fabric OS Reference ...