FEC920: USER GUIDE
Page 147
September 18
Parameter path
Description
Type
Hex
Dec
Resolution
ModbusMaster.6.Data.Mode
Auto Manual mode selection (0 = Auto; 1 = Manual)
uint8
7da0
32160
Not applicable
ModbusMaster.6.Data.Number
Used for multiple instance parameters
uint8
7d18
32024
Not applicable
ModbusMaster.6.Data.ParameterList
Parameter list for a specific slave device
uint8
7cfa
31994
Not applicable
ModbusMaster.6.Data.Priority
Read/Write frequency (as for Modbus Master.1)
uint8
7c29
31785
Not applicable
ModbusMaster.6.Data.PV
Process value received from slave device
float32
7b3c
31548
2dp
ModbusMaster.6.Data.Scaling
Scaling in decimal places for non floating point data types
uint8
7d36
32054
Not applicable
ModbusMaster.6.Data.Send
1 = send the write value to the slave
bool
7cbe
31934
Not applicable
ModbusMaster.6.Data.Set
Sets a digital value (1 = on; 0 = off)
bool
7e00
32256
Not applicable
ModbusMaster.6.Data.SlaveDevice
Slave device to communicate with.
uint8
7b19
31513
Not applicable
ModbusMaster.6.Data.Status
Transaction status (as for Modbus Master.1
uint8
7cdc
31964
Not applicable
ModbusMaster.6.Data.Value
The value to be written to the slave device
float32
7c4c
31820
2dp
ModbusMaster.7.Data.AlarmStatus
Alarm status (as for Modbus Master.1)
uint8
7dc1
32193
Not applicable
ModbusMaster.7.Data.BitPosition
Bit position of the bit of interest in a 16 bit data type
uint8
7d55
32085
Not applicable
ModbusMaster.7.Data.ChanAlarmStatus
Channel alarm status (as for Modbus Master.1)
uint8
7de1
32225
Not applicable
ModbusMaster.7.Data.DataType
Type of data being read/written (as for Modbus Master.1)
uint8
7c0c
31756
Not applicable
ModbusMaster.7.Data.Descriptor
Description for this data item
string_t
6705
26373
Not applicable
ModbusMaster.7.Data.Digital
Digital status (0 = Off, 1 = On)
bool
7e21
32289
Not applicable
ModbusMaster.7.Data.FallBackValue
Fall back value to be written to the slave device
float32
7c8a
31882
2dp
ModbusMaster.7.Data.FunctionCode
The Modbus function code (as for Modbus Master.1)
uint8
7bee
31726
Not applicable
ModbusMaster.7.Data.ModbusAddress
Modbus register address of the data to be read/written
float32
7b98
31640
0dp
ModbusMaster.7.Data.Mode
Auto Manual mode selection (0 = Auto; 1 = Manual)
uint8
7da1
32161
Not applicable
ModbusMaster.7.Data.Number
Used for multiple instance parameters
uint8
7d19
32025
Not applicable
ModbusMaster.7.Data.ParameterList
Parameter list for a specific slave device
uint8
7cfb
31995
Not applicable
ModbusMaster.7.Data.Priority
Read/Write frequency (as for Modbus Master.1)
uint8
7c2a
31786
Not applicable
ModbusMaster.7.Data.PV
Process value received from slave device
float32
7b3e
31550
2dp
ModbusMaster.7.Data.Scaling
Scaling in decimal places for non floating point data types
uint8
7d37
32055
Not applicable
ModbusMaster.7.Data.Send
1 = send the write value to the slave
bool
7cbf
31935
Not applicable
ModbusMaster.7.Data.Set
Sets a digital value (1 = on; 0 = off)
bool
7e01
32257
Not applicable
ModbusMaster.7.Data.SlaveDevice
Slave device to communicate with.
uint8
7b1a
31514
Not applicable
ModbusMaster.7.Data.Status
Transaction status (as for Modbus Master.1
uint8
7cdd
31965
Not applicable
ModbusMaster.7.Data.Value
The value to be written to the slave device
float32
7c4e
31822
2dp
ModbusMaster.8.Data.AlarmStatus
Alarm status (as for Modbus Master.1)
uint8
7dc2
32194
Not applicable
ModbusMaster.8.Data.BitPosition
Bit position of the bit of interest in a 16 bit data type
uint8
7d56
32086
Not applicable
ModbusMaster.8.Data.ChanAlarmStatus
Channel alarm status (as for Modbus Master.1)
uint8
7de2
32226
Not applicable
ModbusMaster.8.Data.DataType
Type of data being read/written (as for Modbus Master.1)
uint8
7c0d
31757
Not applicable
ModbusMaster.8.Data.Descriptor
Description for this data item
string_t
671a
26394
Not applicable
ModbusMaster.8.Data.Digital
Digital status (0 = Off, 1 = On)
bool
7e22
32290
Not applicable
ModbusMaster.8.Data.FallBackValue
Fall back value to be written to the slave device
float32
7c8c
31884
2dp
ModbusMaster.8.Data.FunctionCode
The Modbus function code (as for Modbus Master.1)
uint8
7bef
31727
Not applicable
ModbusMaster.8.Data.ModbusAddress
Modbus register address of the data to be read/written
float32
7b9a
31642
0dp
ModbusMaster.8.Data.Mode
Auto Manual mode selection (0 = Auto; 1 = Manual)
uint8
7da2
32162
Not applicable
ModbusMaster.8.Data.Number
Used for multiple instance parameters
uint8
7d1a
32026
Not applicable
ModbusMaster.8.Data.ParameterList
Parameter list for a specific slave device
uint8
7cfc
31996
Not applicable
ModbusMaster.8.Data.Priority
Read/Write frequency (as for Modbus Master.1)
uint8
7c2b
31787
Not applicable
ModbusMaster.8.Data.PV
Process value received from slave device
float32
7b40
31552
2dp
ModbusMaster.8.Data.Scaling
Scaling in decimal places for non floating point data types
uint8
7d38
32056
Not applicable
ModbusMaster.8.Data.Send
1 = send the write value to the slave
bool
7cc0
31936
Not applicable
ModbusMaster.8.Data.Set
Sets a digital value (1 = on; 0 = off)
bool
7e02
32258
Not applicable
ModbusMaster.8.Data.SlaveDevice
Slave device to communicate with.
uint8
7b1b
31515
Not applicable
ModbusMaster.8.Data.Status
Transaction status (as for Modbus Master.1
uint8
7cde
31966
Not applicable
ModbusMaster.8.Data.Value
The value to be written to the slave device
float32
7c50
31824
2dp
ModbusMaster.9.Data.AlarmStatus
Alarm status (as for Modbus Master.1)
uint8
7dc3
32195
Not applicable
ModbusMaster.9.Data.BitPosition
Bit position of the bit of interest in a 16 bit data type
uint8
7d57
32087
Not applicable
ModbusMaster.9.Data.ChanAlarmStatus
Channel alarm status (as for Modbus Master.1)
uint8
7de3
32227
Not applicable
ModbusMaster.9.Data.DataType
Type of data being read/written (as for Modbus Master.1)
uint8
7c0e
31758
Not applicable
ModbusMaster.9.Data.Descriptor
Description for this data item
string_t
672f
26415
Not applicable
ModbusMaster.9.Data.Digital
Digital status (0 = Off, 1 = On)
bool
7e23
32291
Not applicable
ModbusMaster.9.Data.FallBackValue
Fall back value to be written to the slave device
float32
7c8e
31886
2dp
ModbusMaster.9.Data.FunctionCode
The Modbus function code (as for Modbus Master.1)
uint8
7bf0
31728
Not applicable
ModbusMaster.9.Data.ModbusAddress
Modbus register address of the data to be read/written
float32
7b9c
31644
0dp
ModbusMaster.9.Data.Mode
Auto Manual mode selection (0 = Auto; 1 = Manual)
uint8
7da3
32163
Not applicable
ModbusMaster.9.Data.Number
Used for multiple instance parameters
uint8
7d1b
32027
Not applicable
ModbusMaster.9.Data.ParameterList
Parameter list for a specific slave device
uint8
7cfd
31997
Not applicable
ModbusMaster.9.Data.Priority
FRead/Write frequency (as for Modbus Master.1)
uint8
7c2c
31788
Not applicable
ModbusMaster.9.Data.PV
Process value received from slave device
float32
7b42
31554
2dp
ModbusMaster.9.Data.Scaling
Scaling in decimal places for non floating point data types
uint8
7d39
32057
Not applicable
ModbusMaster.9.Data.Send
1 = send the write value to the slave
bool
7cc1
31937
Not applicable
ModbusMaster.9.Data.Set
Sets a digital value (1 = on; 0 = off)
bool
7e03
32259
Not applicable
ModbusMaster.9.Data.SlaveDevice
Slave device to communicate with.
uint8
7b1c
31516
Not applicable
ModbusMaster.9.Data.Status
Transaction status (as for Modbus Master.1
uint8
7cdf
31967
Not applicable
ModbusMaster.9.Data.Value
The value to be written to the slave device
float32
7c52
31826
2dp
ModbusMaster.10.Data.AlarmStatus
Alarm status (as for Modbus Master.1)
uint8
7dc4
32196
Not applicable
ModbusMaster.10.Data.BitPosition
Bit position of the bit of interest in a 16 bit data type
uint8
7d58
32088
Not applicable
ModbusMaster.10.Data.ChanAlarmStatus
Channel alarm status (as for Modbus Master.1)
uint8
7de4
32228
Not applicable
ModbusMaster.10.Data.DataType
Type of data being read/written (as for Modbus Master.1)
uint8
7c0f
31759
Not applicable
ModbusMaster.10.Data.Descriptor
Description for this data item
string_t
6744
26436
Not applicable
ModbusMaster.10.Data.Digital
Digital status (0 = Off, 1 = On)
bool
7e24
32292
Not applicable
A5E45696052A Rev-AA