13.6.1.2 Setting the input activation mode
This setting requires selecting two possible options: activation on closing (equivalent to normally open)
or activation on opening (equivalent to normally closed)�
For activation on closing, send the following SMS message:
<user code>.I1.C
Note
: No response SMS message is required from the chronothermostat 01913�
Example�
If the set user code is the default 1234 and you want the alarm to be generated when the input detects
voltage at its ends, send the following SMS:
1234.I1.C
For activation on opening, send the following SMS message:
<user code>.I1.O
Note
: No response SMS message is required from the chronothermostat 01913�
Example�
If the set user code is the default 1234 and you want the alarm to be generated when the input detects
no voltage at its ends, send the following SMS:
1234.I1.O
13.6.1.3 Setting the input activation time
This setting enables defining a time interval for activating the input� The chronothermostat detects the
state of activation only when the alarm condition has been maintained for the entire duration of the
set activation time�
For setting the input activation time send the following SMS message:
<user code>.I1.TON.<time>
where
<time>
is the time of activation, expressed in ms (milliseconds)�
Note
: No response SMS message is required from the chronothermostat 01913�
Example�
If the set user code is the default 1234 and you want to set an activation time of 2 s, send the following
SMS:
1234.I1.TON.2000