4.3 Main Commands
4-33
4
4.3.26
Constant Speed Feed (FEED: 36H)
Byte
FEED
Description
Command
Response
1
36H
36H
Processing
classifications
Motion command
group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Within communi-
cations cycle
Subcommand
Can be used.
3
OPTION
STATUS
• Performs constant speed feeding using the target speed (TSPD). Use the Stop
Motion command (HOLD: 25H) to stop the constant speed feeding. The posi-
tion control loop is effective during this command.
• Can be used during phases 2 and 3.
• A command warning will occur and the command will be ignored in the fol-
lowing cases.
- During phase 1: MECHATROLINK-II command warning (A.95)
- If the SERVOPACK is Servo OFF:
MECHATROLINK-II command warning (A.95)
- If the target speed (TSPD) exceeds the limit: Parameter setting warning
(A.94)
• OPTION can be selected. Refer to
4.5.2 Option Field Specifications:
OPTION
for details.
• The target speed (TSPD) is a signed 4 bytes. The direction is determined by
the sign. It is set using units/s.
• Changes can be made to the target speed during movement.
• Use DEN (output complete) to confirm the completion of position reference
output.