TRIGger
The
TRIGger
command subsystem controls the behavior of the trigger system once
it is initiated (see
INITiate
command subsystem).
Figure 5-5 shows the overall Trigger System model. The shaded area shows the
ARM
subsystem portion.
Note
The
ARM
system only exists while
TRIGger:SOURce
is
TIMer
or while the Continuous
Mode is set (
TRIGger:SOURce IMMediate
and
INITiate:CONTinuous ON
). When
neither of the above conditions are true, SCPI compatibility requires that
ARM:SOURce
be set to
IMMediate
or Error -221, “ Settings conflict” will be generated.
Trigger
Timer
Trigger
Enable
Trigger
Counter
BUS
External
HOLD
IMMediate
TTLTrg<n>
SCP Trig
ARM:SOURce <source>
TRIGger:TIMer <interval>
Only while
INIT:CONT is ON
&
TRIG:SOUR is IMM
TRIGger:SOURce <source>
Internal
Trigger Signal
TRIGger:COUNt <count>
TIMer
Figure 5-5. Logical Trigger Model
TRIGger
266 HP E1313/E1413 Command Reference
Chapter 5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com