For resistance temperature measurements (
[SENSe:]FUNCtion:TEMPerature
) the
Current Source SCP must be set as follows:
Required Current Amplitude Temperature Sensor Types and Subtypes
MAX (488
µ
A)
MIN (30
µ
A)
RTD,85 | 92 and THER,2250
THER,5000 | 10000
•
When
*CAL?
is executed, the current sources are calibrated on the range selected
at that time.
•
This command will cause Error +3000, “ illegal while initiated” if trigger is initiated.
•
Related Commands:
*CAL?
,
OUTPut:CURRent:AMPLitude?
•
*RST Condition:
MIN
Usage
OUTPut:CURRent:AMPLitude 488ua,(@116:123)
Set Current Source SCP at channels 16
through 23 to 488
µ
A.
OUTP:CURR:AMPL 30E-6,(@105)
Set Current Source SCP at channel 5 to 30
µ
A.
OUTPut:CURRent:AMPLitude?
OUTPut:CURRent:AMPLitude? (@<
channel
>)
returns the range setting of the
Current Source SCP channel specified by
<
channel
>
.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
<
channel
>
channel list (string)
100 - 163
none
Comments
•
<
channel
>
must specify a single channel only.
•
If
<
channel
>
specifies an SCP which is not a Current Source, Error +3007,
“ Invalid signal conditioning module” is generated.
•
Returned Value: Numeric value of amplitude set.
The C-SCPI type returned is float32.
•
Related Commands:
OUTPut:CURRent:AMPLitude
Usage
OUTP:CURR:AMPL? (@163)
Check SCP current set for channel 63
(r3.0E-5 or +4.88E-4).