3.1.2 OPC
DESCRIPTION
The *OPC (Operation Complete) command sets the OPC bit (bit
0) in the standard Event Status Register (ESR). This command
has no other effect on the operation of the device because the
instrument starts parsing a command or query only after it has
completely processed the previous command or query.
The *OPC? query always responds with the ASCII character 1
because the device only responds to the query when the
previous command has been entirely executed.
COMMAND SYNTAX
*OPC
QUERY SYNTAX
*OPC?
RESPONSE FORMAT
*OPC 1
3.1.3 CLS
DESCRIPTION
The *CLS command clears all the status data registers.
COMMAND SYNTAX
*CLS
EXAMPLE
The following command causes all the status data registers to be
cleared:
*CLS