25
Note:
There are some parameters Value depends on the model, You can read
version datasheet to get specific parameters
QUERY SYNTAX
<channel>: MDWV (MoDulateWaVe)?
<channel>:={C1, C2}
RESPONSE
FORMAT
<channel>:MDWV <parameter>
<parameter> :={ Return all parameter of the current modulation
parameters.}
EXAMPLE
Set channel one modulation type to AM.
C1: MDWV AM
Set modulation shape to AM, and set AM modulating wave type
to sine wave.
C1: MDWV AM, MDSP, SINE
Read channel one modulation parameters of which STATE is ON.
C1: MDWV?
Return:
C1:MDWV STATE,ON,AM,MDSP,SINE,SRC,INT,FRQ,100HZ,
DEPTH,100,CARR,WVTP,RAMP,FRQ,1000HZ,AMP,4V,OFST,0V,PHSE,
0, SYM, 50
Read channel one modulate wave parameters of which STATE is
OFF.
C1: MDWV?
Return:
C1: MDWV STATE, OFF
Set channel one FM frequency to 1000Hz
C1: MDWV FM, FRQ, 1000
Set channel one carrier shape to SINE.
C1: MDWV CARR, WVTP, SINE
Set channel one carrier frequency to 1000 Hz.
C1: MDWV CARR, FRQ,1000
RELATED
COMMANDS
ARWV, BTWV, SWWV, BSWV
Note: