RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
18
Private
MIB
Parameters
Chapter
C
winlink1000OduAirTxOperationMo
de
1.3.6.1.4.1.4458.1000.1.5.5
9
Integer
RW This
parameter
controls
the
Operation
mode
of
frames
sent
over
the
air.
The
Operation
mode
is
either
normal
(1)
for
regular
transmission
where
frame
size
is
determined
by
the
traffic
or
throughput
test
(2)
when
the
user
requests
an
actual
over
the
air
throughput
estimation
using
full
frames.
The
latter
lasts
no
more
than
a
predetermined
interval
(default
30
sec).
winlink1000OduAirDesiredNetMast
erTxRatio
1.3.6.1.4.1.4458.1000.1.5.6
0.1
Integer
RW This
parameter
is
reserved
to
the
element
manager
provided
with
the
product.
winlink1000OduAirCurrentNetMast
erTxRatio
1.3.6.1.4.1.4458.1000.1.5.6
0.2
Integer
RO
Represents
the
actual
Net
Master
Tx
RAtio.
winlink1000OduAirMinUsableMast
erTxRatio
1.3.6.1.4.1.4458.1000.1.5.6
0.3
Integer
RO
Represents
the
minimal
value
the
user
can
configure
for
Desired
net
mAster
Tx
Ratio.
winlink1000OduAirMaxUsableMast
erTxRatio
1.3.6.1.4.1.4458.1000.1.5.6
0.4
Integer
RO
Represents
the
maximal
value
the
user
can
configure
for
Desired
net
mAster
Tx
Ratio.
winlink1000OduAirAccumulatedUA
S
1.3.6.1.4.1.4458.1000.1.5.6
1
Integer
RO
Accumulates
the
Unavailable
seconds
of
the
Air
Interface.
Relevant
for
point
to
point
systems.
winlink1000OduAirDistStr
1.3.6.1.4.1.4458.1000.1.5.6
2
DisplayString
RO
Possibilities
of
the
link
according
to
RFP
and
CBW
winlink1000OduAirChannelsDefault
FreqStr
1.3.6.1.4.1.4458.1000.1.5.6
3
DisplayString
RO
A
string
representing
the
channels
available.
Each
character
represents
one
frequency
when
'1'
means
its
available
and
'0'
means
its
not.
winlink1000OduAirAntConnectionT
ype
1.3.6.1.4.1.4458.1000.1.5.6
4
Integer
RW Antenna
connection
type
(External(1)
Integrated(2)
Embedded_External(3)
Embedded_Integrated(4)
).
winlink1000OduAirAllowableChann
elsStr
1.3.6.1.4.1.4458.1000.1.5.6
5
DisplayString
RW A
string
representing
the
allowable
channels.
Each
character
represents
one
channel
when
'1'
means
its
available
and
'0'
means
its
not.
winlink1000OduAirDfsAlgorithmTyp
eState
1.3.6.1.4.1.4458.1000.1.5.6
6.1
Integer
RW Bitmap
for
state
of
Radar
Algorithm
Type.
Filters
by
bit's
position:
0
=
Zero
PW
1
=
Fixed
2
=
Variable
3
=
Staggered
4
=
Long.
winlink1000OduAirDfsLastDetected
Tbl
N/A Last
detected
radars
table.
winlink1000OduAirDfsLastDetected
Entry
N/A ODU
Multi
‐
band
Sub
Bands
Table
entry.
INDEX
{
winlink1000OduAirDfsLastDetectedIndex
}
winlink1000OduAirDfsLastDetected
Index
1.3.6.1.4.1.4458.1000.1.5.6
6.2.1.1
Integer
RO
Dfs
Last
Detected
Radars
Table
Index.
winlink1000OduAirDfsLastDetected
Time
1.3.6.1.4.1.4458.1000.1.5.6
6.2.1.2
TimeTicks
RO
Dfs
time
of
the
last
detected
radar.
winlink1000OduAirDfsLastDetected
AlgorithmType
1.3.6.1.4.1.4458.1000.1.5.6
6.2.1.3
Integer
RO
Dfs
type
of
the
last
detected
radar.
winlink1000OduAirDfsLastDetected
Frequency
1.3.6.1.4.1.4458.1000.1.5.6
6.2.1.4
Integer
RO
Dfs
frequency
of
the
last
detected
radar.
winlink1000OduAirPreferredChann
elsStr
RW A
string
representing
the
preferred
channels.
Each
character
represents
one
channel
when
'1'
means
its
preferred
and
'0'
means
its
not.
winlink1000OduAirSyncLossThresh
old
RW When
the
current
throughput
is
below
this
threshold
(in
Kbps)
sync
loss
will
occur.
winlink1000OduAirGeoLocation
1.3.6.1.4.1.4458.1000.1.5.6
9
DisplayString
RW Geographic
device
location
in
format:
latitude
longitude.
winlink1000OduAirAggregateCapaci
ty
1.3.6.1.4.1.4458.1000.1.5.7
0
Integer
RO
Aggregate
Capacity
of
the
ODU
in
Mbps.
winlink1000OduAirALPMDataBuffer
Str
RW a
string
that
holds
all
of
the
ALPM
events
data
winlink1000OduPerfMonCurrTable
N/A This
table
defines/keeps
the
counters
of
the
current
15
min
interval.
Table
C
‐
2:
Private
MIB
Parameters
(Sheet
13
of
32)
Name
OID
Type
A
cce
ss
Description
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......