Programming the Agitate Step Type
The Agitate Step Type allows the owner to program the agitate
steps of a cycle. After selecting the desired Cycle Step number
and pressing START (enter),
XXAgit
will appear in the display.
Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
) key-
pad to scroll through the options and START (enter) to select a
value.
Step
Type
Diplay A
Display B
Values
Description
XXAgit
Agitate Step Type (
XX
is step number, step type is
flashing)
En diS
XXAg01
EnAbLE
,
diSAbL
,
dNod
1
,
dNod 2
Step Enable/Disable
Choosing
dNod 1
and
dNod 2
will enable the step
if the cycle modifier is chosen and set to be enabled
in
Cycle Modifier Programming CNP-
.
StAtUS
XXAg02
PrEWSH
,
WASH
,
rinSE1
,
rinSE2
,
rinSE3
,
rinSE4
,
SPin
Status LED: The corresponding LED on the control
will be lit during this step.
NinUtE
XXAg03
0-255
Step Minutes: If Programmed Cycle Time Display is
enabled and set to a value greater than zero, it will
override this time.
SECond
XXAg04
0-59
Step Seconds: If Programmed Cycle Time Display is
enabled and set to a value greater than zero, it will
override this time.
HEAt
XXAg05
no
,
tArgEt
,
MAintA
Heater Temperature
rAtE
XXAg06
no
,
0.5 - 6.0
(°F/Minute),
0.3 - 3.3
(°C/Minute)
Heat Rate
rotAtE
XXAg07
3-255
Motor On Time (seconds)
PAUSE
XXAg08
3-255
Motor Off Time (seconds)
SPEEd
XXAg09
no rot
,
LoW Ag
,
rEg
Ag
10 - 50 RPMs (0.03 - 0.77
G Force)
Rotation Speed
rEvErS
XXAg10
rEv on
,
no rEv
Reversing
drAin1
XXAg11
oFF
,
on
Drain
rEFiLL
XXAg13
oFF
,
on
Refill: If the water level drops while in the step, wa-
ter will be added until the last set water level set by
the last run fill step is reached.
oUtP 1
XXAg15
oFF
,
on
External Output #1
oUtP 2
XXAg16
oFF
,
on
External Output #2
oUtP 3
XXAg17
oFF
,
on
External Output #3
Table 16
continues...