11.PROGRAMMING DIGITAL INPUTS AND OUTPUTS
11.1.
The pico-PLC
The internal pico-PLC is used to connect the external world (inputs/outputs) with the world of the
parameters of the SLVD-N. The PLC can be used to copy digital input to a binary parameter, to copy a
binary parameter to a digital output and to execute mathematical and Boolean operations. The PLC
program must be inserted as a list of instructions by using the keyboard or by the serial line using a PC
and an interface program. A PLC program (see
Appendix F
) written to meet the needs of a large
number of applications corresponds to the default parameters (b99.12). In most cases it is not
necessary to program the PLC itself. The main features of the pico-PLC are:
program
steps 256
scanning
time
6.144
ms
number of timers
2
number of instructions
15
stack
depth
1
mathematical operations
16 / 32 bits
fast
inputs
2
–
(512
μ
s)
PLC PARAMETERS
Par. Description
Field
Range
Def. Res.
Pr71
Constant value = -1.
Double word.
R/W -32768÷+32767 -1 1
Pr72
Constant value = 0.
Double word.
R/W -32768÷+32767 0 1
Pr73
Constant value = 1.
Double word.
R/W -32768÷+32767 1 1
Pr74
Constant value = 2.
Double word.
R/W -32768÷+32767 2 1
Pr75
Constant value = 10.
Double word.
R/W -32768÷+32767 10 1
Pr76
Constant value = 100.
Double word.
R/W -32768÷+32767 100 1
Pr77
Constant value = 1000.
Double word.
R/W -32768÷+32767
1000
1
Pr78
Constant value = 1024.
Double word.
R/W -32768÷+32767
1024
1
Pr79
Constant value = 4096.
Double word.
R/W -32768÷+32767
4096
1
Pr80
Free parameter.
A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr81
Free parameter.
A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr82
Free parameter.
A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr83
Free parameter.
A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr84
Free parameter.
A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr85
Free parameter.
A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr86
Free parameter.
A parameter that can be stored
by the user (word).
R/W -32768÷+32767 0 1
Pr87
Parametro libero.
Parametro memorizzabile a
disposizione dell’utente (word).
R/W -32768÷+32767 0 1