Parker Hannifin S.p.A S.B.C. Division
SLVDN User’s Manual
Page 134 of 181
PDO 4 tx :
[0x6041]
status word
[0x6063]
position feedback in counts
[0x6064]
position feedback in counts (normally in user unit in this case as
well in counts)
[0x2060]
Word composed with digital input and aux analog input .
b0:
In0
b1:
In1
b2:
In2
b3:
In3
b4..b15 Analog input aux.
Life guarding protocol is implemented and can be activated writing life time factor and guard
time besides a missing guarding event ,life guarding protocol can be triggered by a missing
sync (if b271.8=1) or a bus-off condition. In any case state machine present state of ds301
communication can be changed according to what is set in the object 0x1029 ‘error
behaviour’ (0 enter pre-operational , 1 no change , 2 stop).
Note NMT commands are handled every 1.024 msec, so subsequent commands should be sent
to the drive not closer than 1.204 msec including broadcast NMT commands.
13.1.1.
Dictionary object summary of ds301 in SLVD-N
[0x1000] : device type
[0x1001] : error register
[0x1005] : sync cob-id
[0x1006] : communication cycle period
[0x100c] : guard time
[0x100d] : life time factor
[0x1014] : Cob-Id Emergency object
[0x1017] : Producer heartbeat time
[0x1018] : Identity object
[0x1029] : Error behaviour
[0x1200] : SDO server parameters
//pdo
[0x1400] : PDO 1 rx communication parameters
[0x1401] : PDO 2 rx communication parameters
[0x1403] : PDO 4 rx communication parameters
[0x1600] : PDO 1 rx mapping parameters
[0x1601] : PDO 2 rx mapping parameters
[0x1603] : PDO 4 rx mapping parameters
[0x1800] : PDO 1 tx communication parameters
[0x1801] : PDO 2 tx communication parameters
[0x1803] : PDO 4 tx communication parameters
[0x1a00] : PDO 1 tx mapping parameters
[0x1a01] : PDO 2 tx mapping parameters
[0x1a03] : PDO 4 tx mapping parameters