15
4.4
Detailed Command Structure
4.4.1
Request Analog Monitor Readbacks
Description:
The host requests that the firmware transmit the present values of
Analog Monitor Readbacks. All read back values are in the range 0
– 4095. See the scaling summary table after the description of
values to convert from scaled value to actual value of voltage or
current. Please note that the voltage scaling for the monitor
voltages is not the same as their respective set values.
Direction:
Host to supply
Syntax:
<STX><19><,><CSUM><ETX>
Example:
<STX><19>,<CSUM><ETX>
Response:
<STX><19><,><ARG1><,><ARG2><,><ARG3<,><ARG4><,><AR
G5><,><ARG6><,><ARG7><,><ARG8><,><ARG9><,><ARG10><
,><ARG11><,><ARG12><,><ARG13><,><ARG14><,><ARG15><,
><ARG16><,> <CSUM><ETX>
Where: (ARG# in ASCII format)
ARG1 = +15V = 0 – 4095 (scaling = 0.0062256 V/Bit)
ARG2 = -15V = 0 – 4095 (0.0043663*ARG – 16.4665)
ARG3 = +24V = 0– 4095 (0.0104762 V/Bit)
ARG4 = +3.3Va = 0 – 4095 (0.00310847 V/Bit)
ARG5 = +3.3Vb = 0– 4095 (0.0011978 V/Bit)
ARG6 = TBD
ARG7 = TBD
ARG8 = TBD
ARG9 = Filament Voltage Monitor = 0-4095 = 0–11.78V
ARG10 = KV Feedback Monitor = 0-4095 = 0-53,476V
ARG11 = MA Feedback Monitor = 0-4095 = 0-213.828mA
ARG12 = DC Voltage Monitor = 0-4095 = 0-346.4V
ARG13 = Leak Limit monitor = 0–4095 = 106.914
ARG14 = Filament Feedback Monitor = 0–4095 = 0-6.415A
ARG15 = GND Monitor = (0.000732V/Bit)
ARG16 = TBD
Description of Monitored Values: