MX-2100/2104
Installation and Operation Manual
Appendix F Command Set Description
Commands
F-55
Use
1. To perform software download to KVF.6 or KVF.8 module installed in the
MX-2100, type:
LOAD IO i <ENTER>
where i is the I/O slot number (1 through 12)
2. Wait until the TST LED in the card starts to blink. Connect your download
cable to the specified DL connection in the card and connect the other end to
one of the communication ports in the PC. Use your download application in
the PC to load the software.
LOOP
Purpose
Activate tests. For main link test loops, you can define their duration: after the
specified time, the loop is automatically disconnected. If you do not specify the
loop duration, it remains permanently connected.
•
Refer to the
Diagnostics
chapter for the allowable loop combinations.
•
Refer to the
Diagnostics
chapter for a description of the loops available on the
MX-2100 main link.
•
Refer to the relevant module Installation and Operation Manual, for a
description of the tests available on the corresponding module.
Format
LOOP [loopname] {ML A ML B i:j}
or
LP [loopname] {ML A ML B i:j}
Use
1. To activate a specific type of loop on main link A, type:
LOOP L ML A <ENTER>
or
LP L ML A <ENTER>
LOOP V54.2 ML A <ENTER>
or
LP V54.2 ML A <ENTER>
LOOP V54.3 ML A <ENTER>
or
LP V54.3 ML A <ENTER>
2. To activate a specific type of loop on main link B, type:
LOOP L ML B <ENTER>
or
LP L ML B <ENTER>
LOOP V54.2 ML B <ENTER>
or
LP V54.2 ML B <ENTER>
LOOP V54.3 ML B <ENTER>
or
LP V54.3 ML B <ENTER>
If MX-2100 operates in the SINGLE mode, it is not necessary to specify the link, e.g.,
you can type LOOP L ML <ENTER> instead of LOOP L ML A <ENTER> or LOOP L
ML B <ENTER>.
3. To activate a test or loop on the desired channel, type:
LOOP L i:j <ENTER>
or
LP L i:j <ENTER>
LOOP R i:j <ENTER>
or
LP R i:j <ENTER>
Note