17-72
SCPI Command Reference
:STARt <n>
:STOP <n>
:SOURce[1]:CURRent:STARt <n>
Specify start current level (current sweep)
:SOURce[1]:VOLTage:STARt <n>
Specify start voltage level (voltage sweep)
:SOURce[1]:CURRent:STOP <n>
Specify stop current level (current sweep)
:SOURce[1]:VOLTage:STOP <n>
Specify stop voltage level (voltage sweep)
Parameters
<n> =
-105e-3 to 105e-3
Set I-Source level (amps)
-210 to 210
Set V-Source level (volts)
DEFault
0A or 0V
MINimum
-105e-3A or -210V
MAXimum
+105e-3A or +210V
Query
:STARt?
Query start level for sweep
:STARt? DEFault
Query *RST default level
:STARt? MINimum
Query lowest allowable level
:STARt? MAXimum
Query highest allowable level
:STOP?
Query start level for sweep
:STOP? DEFault
Query *RST default level
:STOP? MINimum
Query lowest allowable level
:STOP? MAXimum
Query highest allowable level
Description
These commands are used to specify the start and stop levels for a sweep. If
using a
fi
xed (manual) source range, the sweep will be performed using a
source range that will accommodate all source values (Best Fixed Range).
You can use source auto range if sweeping through one or more source
ranges.
When the sweep is started, the source will output the speci
fi
ed start level
and, after the delay period of the SDM cycle, a measurement is performed.
The sweep continues until the source outputs the speci
fi
ed stop level. At this
level, the instrument again performs another measurement (after the SDM
delay) and then stops the sweep.
The source-measure points in a sweep can be set by specifying a step size,
or by specifying the number of source-measure points in the sweep. Refer to
:STEP and :POINts.
:STARt and :STOP are coupled to :CENTer and :SPAN. Thus, when start
and stop values are changed, the values for center and span are affected as
follows:
Center = (Start + Stop) / 2
Span = Stop - Start
Summary of Contents for 6430
Page 26: ......
Page 32: ......
Page 78: ...2 14 Connections ...
Page 98: ...3 20 Basic Source Measure Operation ...
Page 138: ...5 30 Source Measure Concepts ...
Page 156: ...6 18 Range Digits Speed and Filters ...
Page 168: ...7 12 Relative and Math ...
Page 176: ...8 8 Data Store ...
Page 202: ...9 26 Sweep Operation ...
Page 248: ...11 22 Limit Testing ...
Page 310: ...16 6 SCPI Signal Oriented Measurement Commands ...
Page 418: ...17 108 SCPI Command Reference ...
Page 450: ...18 32 Performance Verification ...
Page 477: ...A Specifications ...
Page 489: ...B StatusandErrorMessages ...
Page 498: ...B 10 Status and Error Messages ...
Page 499: ...C DataFlow ...
Page 503: ...D IEEE 488BusOverview ...
Page 518: ...D 16 IEEE 488 Bus Overview ...
Page 519: ...E IEEE 488andSCPI ConformanceInformation ...
Page 523: ...F MeasurementConsiderations ...
Page 539: ...G GPIB488 1Protocol ...
Page 557: ......