SCPI Command Reference
17-13
Table 17-6
SOURce command summary
Command
Description
Default
parameter SCPI
Source
memory
:SOURce[1]
:CLEar
[:IMMediate]
:AUTO <b>
:AUTO?
:MODE <name>
:MODE?
:FUNCtion
[:MODE] <name>
[:MODE]?
:DELay <n>
:AUTO <b>
:AUTO?
:DELay?
:CURRent
:MODE <n>
:MODE?
:RANGe <n>|UP|DOWN|
:AUTO <b>
:AUTO?
:RANGe?
[:LEVel]
[:IMMediate]
[:AMPLitude] <n>
[:AMPLitude]?
:TRIGgered
[:AMPLitude] <n>
[:AMPLitude]?
:SFACtor <n>
:STATe <b>
:STATe?
:SFACtor?
:STARt <n>
Path to control sourcing:
Path to clear source:
Turn selected source off.
Enable or disable auto clear for source.
Query state of auto clear.
Specify auto clear mode (ALWays or
TCOunt).
Query auto clear mode.
Source selection:
Select source mode (VOLTage, CURRent or
MEMory).
Query source selection.
Specify settling time (in sec): 0 to 9999.999.
Enable or disable auto settling time.
Query state of auto settling time.
Query source settling time.
Path to con
fi
gure I-Source:
Select I-Source mode (FIXed, SWEep, or
LIST).
Query I-Source mode.
Select
fi
xed I-Source range; 0 to 0.105.
Enable or disable autoranging.
Query state of autoranging.
Query I-Source range setting.
Set I-Source level (in amps):
Set level immediately:
Specify current level; -0.105 to 0.105.
Query current level.
Set level when triggered:
Specify current level; -0.105 to 0.105.
Query current level.
Set current scaling factor (-999.9999e+18
to +999.999e+18).
Enable/disable current scaling factor.
Query current scaling factor state.
Query current scaling factor.
Specify start level for I-sweep; -105e-3 to
105e-3.
OFF
ALWays
VOLTage
0.003
OFF
FIXed
1.05e-4
ON
0
0
1.0
OFF
0
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
1
✓
1
✓
1
✓
1
1
If source V is active.
Summary of Contents for 6430
Page 26: ......
Page 32: ......
Page 78: ...2 14 Connections ...
Page 98: ...3 20 Basic Source Measure Operation ...
Page 138: ...5 30 Source Measure Concepts ...
Page 156: ...6 18 Range Digits Speed and Filters ...
Page 168: ...7 12 Relative and Math ...
Page 176: ...8 8 Data Store ...
Page 202: ...9 26 Sweep Operation ...
Page 248: ...11 22 Limit Testing ...
Page 310: ...16 6 SCPI Signal Oriented Measurement Commands ...
Page 418: ...17 108 SCPI Command Reference ...
Page 450: ...18 32 Performance Verification ...
Page 477: ...A Specifications ...
Page 489: ...B StatusandErrorMessages ...
Page 498: ...B 10 Status and Error Messages ...
Page 499: ...C DataFlow ...
Page 503: ...D IEEE 488BusOverview ...
Page 518: ...D 16 IEEE 488 Bus Overview ...
Page 519: ...E IEEE 488andSCPI ConformanceInformation ...
Page 523: ...F MeasurementConsiderations ...
Page 539: ...G GPIB488 1Protocol ...
Page 557: ......