185
(5) Parameter write-in and read-out (readable and writable)
Address
Content
Data length
0x0300
~0x0363
PA
□□
:
50 parameters
2 words
0x0400
~0x0463
PB
□□
: 50 parameters
2 words
0x0500
~0x0577
PC
□□
: 60 parameters
2 words
0x0600
~0x064F
PD
□□
:
40 parameters
2 words
0x0700
~0x07C5
PE
□□
:
99 parameters
2 words
0x0800
~0x08C5
PF
□□
:
99 parameters
2 words
(6) Factory-set recovery (readable and writable)
Address
Content
Data length
0x0140
All parameters would be recovered factory-set 1 second later once
“1EA5h” being written. To read this address, the result of “1” means
the recovery is processing.
“0” means the completion of recovery.
1 word
(7) DI contact control (readable and writable)
Step 1: Select DI on/off control source option
Address
Content
Data length
0x061E
DI on/off control source option
(PD16)
Each bit is to decide the on/off control source of corresponding DI.
Bit0 is corresponding to DI1, bit1 is corresponding to DI2, bit2 is
corresponding to DI3, and so on.
0
:
The specified DI is controlled by the actual wirings.
1
:
The specified DI is controlled by communication software. (PD25)
2 word
Step 2: Write command to control on/off state of each DI pin
Address
Content
Data length
0x0630
Use bit value to control the corresponding Di on/off state.
0
:
denotes
“off” state.
1
:
denotes
“on” state.
2 words
bit No.
b12~b31
b11
b10
b9
b8
b7
B6
b5
b4
b3
b2
b1
b0
DI
0
DI12
DI11
DI10
DI9
DI8
DI7
DI6
DI5
DI4
DI3
DI2
DI1
Summary of Contents for SDE Series
Page 13: ...5 1 6 Function block diagram ...
Page 26: ...18 3 3 3 CN1 pin name list ...
Page 223: ...215 SME L040 SME L075 SME L100 SME L150 ...
Page 224: ...216 SME L200 SME L300 SME M100 SME M150 Continuous running range ...
Page 227: ...219 ...
Page 231: ...223 4 Wiring example with peripheral equipment CN2 Encoder socket ...
Page 242: ...234 12 4 Version information Version V1 01 Issue date Aug 2017 Proofreader Yaochou Shu ...