84
enable function, when the DI1 is valid, the servo S-ON.
DI1
/S-ON
Terminal
effective
Enable
effective
Terminal
invalid
Enable
invalid
Terminal
invalid
Enable
invalid
The different DI can be set to the same function, the corresponding logical relations is ―and‖, that when the D1& effective, the
corresponding function of the event will occur. Such as P6-03=1, P6-02=1, DI1 and DI2 at the same time effective, servo ON; when there
is an invalid, servo OFF.
DI1
DI2
/S-ON
Terminal
invalid
Enable
effective
Terminal
effective
Terminal
effective
Terminal
invalid
Terminal
invalid
Terminal
invalid
Terminal
effective
Enable
invalid
Enable
invalid
Table7-5 Digital input (DI) function definition table
Setting
Name
Function
Description
Trigger mode
Operation
mode
0
Disabled Terminal invalid
1
S-ON Servo enable
ON- servo motor power on
enable
OFF- servo motor enable
disabled
Level
triggered
P S T
2
ALM-RST Alarm reset signal
ON- in the case of abnormal
conditions has been lifted,
reset the fault and alarm can
be reset.
Edge Trigger
P S T
3
P-CLR
Position control pulse
deviation counter
clear
Trigger mode refer to P1-34
definition
Edge/ Level
Trigger
P
4
DIR-SEL
Speed instruction
direction selection
OFF- default command
direction
ON- directive reverse
direction
Level
triggered
S
5
CMD0
Internal instruction
bit0
In position mode control, the
signal is a position
multi-segment switching
function;
In speed mode control, the
signal is the speed
multi-segment switching
function
Level
triggered
P S
6
CMD1
Internal instruction
bit1
Level
triggered
P S
7
CMD2
Internal instruction
bit2
Level
triggered
P S
8
CMD3
Internal instruction
bit3
Level
triggered
P S
9
CTRG
Internal instruction
trigger
Multi
position
trigger
condition
Edge Trigger
P
10
MSEL
Control Mode
switching
Used to mixed Mode Control
switching
Level
triggered
P S T
11
ZCLAM
P
Analog speed
command Enable
fixed zero
OON- zero fixed function
enable
OOFF- zero fixed function
ban
Level
triggered
S
12
INHIBIT Pulse inhibit
ON- prohibit instruction pulse
input
OFF-allow instruction pulse
Level
triggered
P