88
P7-02=0
:
No parity 1+8+N+1
;
P7-02=1
:
Odd parity check 1+8+O+1
;
P7-02=2
:
even-parity check 1+8+E+1
;
P7-02=3
:
No parity 1+8+N+2
;
P7-02=4
:
Odd parity check 1+8+O+2
;
P7-02=5
:
Odd parity check 1+8+E+2
;
7.9 P8-xx Auxiliary check even-parity function parameters
P8-00
Software Reset
Initail value
Unit
Communication
Address
0
-
2800H
Control Mode
:
P S T
Range
:
0
~
1
Data size
:
16bit
Display mode
:
Decimal system
Parameter function
:
Software Reset
,
all the values of the function parameters will be returned to the set value. Effect is equivalent to power off
reset.
P8-00=0
:
No operation
P8-00=1
:
System software reset, executed once
P8-01
Fault Reset
Initail value
Unit
Communication
Address
0
-
2801H
Control Mode
:
P S T
Range
:
0
~
1
Data size
:
16bit
Display mode
:
Decimal system
Parameter function
:
Reset driver alarm and fault
P8-01=0
:
No operation
P8-01=1
:
Alarm and fault reset, automatic reset after completion. If the fault cannot reset, this function is invalid.
P8-02
Dynamic function
Initail value
Unit
Communication
Address
0
-
2802H
Control Mode
:
P S T
Range
:
0
~
1
Data size
:
16bit
Display mode
:
Decimal system
Parameter function
:
More are available at P8-03Parameter function
P8-03
Jog Speed
Initail value
Unit
Communication
Address
0
rpm
2803H
Control Mode
:
P S T
Range
:
0
~
motor rated speed
Data size
:
16bit
Display mode
:
Decimal system
Parameter function
:
Set the drive to receive the running speed of the motor when it is running.
In order to avoid the system run directly uncontrollable incidents caused by loss, after the initial installation of the system or replacement
device, it is recommended with a dynamic function test run. Move the operation process are as follows:
Display
SET
>
The motor is running at speed of P8-03 , release it , then the
motor is stopped.
<
The motor is running at speed of P8-03 In the opposite
direction, release it , then the motor is stopped.
MODE
Exit Jog operation mode
P8-03
P8-02
Set the speed of Jog operation
JOGEn
Press Key
To be safety, speed should not be too large, generally not more than 10% of the rated speed of the motor
Press Key
Press Key
Press Key
P8-04
Off-line inertia identification
Initail value
Unit
Communicatio
n Address
0
-
2804H
Control Mode
:
P S T
Range
:
0
~
1
Data size
:
16bit
Display mode
:
Decimal system
Parameter function
:
Triangle wave
injection method is used to study the load
spd
t
0
Forward
Forward
Reverse