3.25.6.
AT#DWSTATUS - Query Connection Status
The command purpose is to query the IoT Portal to receive the status of the connection,
including some runtime statistics.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
No
No
-
2
AT#DWSTATUS
Execution command returns the status of the connection, including some runtime
statistics. Note, all statistics should be stored in RAM, not NVM.
Additional info:
The IoT Portal will return a generic structure:
#DWSTATUS:
<connected><lastErrorCode>,<latency>,<pktsIn>,<pktsOut>,<bytesIn>,<bytesOu
t>
Name
Type
Default
Description
<connected>
integer
N/A
Connection status.
Values:
3 : waiting to connect
2 : connected
1 : trying to connect
0 : disconnected
<lastErrorCode> integer
-
last error code encountered by the
client.
<latency>
integer
-
milliseconds measured between last
request and reply.