117
is turned on. The instruction data byte bit corresponds to the step of the current step of the instrument as
shown in below table
:
Data Byte
Step Connection Status
0x00
This command is used to turn on the step connection of the
current step. Command is invalid when output is turned on.
0x01
This command is used to turn off the step connection of the
current step. Command is invalid when output is turned on.
2)
Send Instruction Format
Instrument
address
Function
code
High
address
Low
address
High
bytes
Low
bytes
Number
of data
Data
byte 1
Data
byte 2
CRC
Low
CRC
High
1~32
0x10
0x00
0x24
0x00
0x01
0x02
0x00
0x00
or
0x01
Calculated based
on the first 8 bytes
3)
Return Instruction Format
6.4.2.36
Address 37(AP High Limit)
1)
Command Description
This command is used to set the peak current high limit value of the current step in the programmed
mode. When the voltage mode is "AUTO" and the voltage is less than 150V, the range is 0.0~33.6A; when
the voltage mode is "AUTO" and the voltage is greater than 150V or the voltage mode is "HIGH", the
range is 0.0~16.8A. When this parameter is set to 0.0, this function is turned off. Command is invalid when
output is turned on.
2)
Send Instruction Format
Instrument
address
Function
code
High
address
Low
address
High
bytes
Low
bytes
Number
of data
Data byte 1~4
CRC
Low
CRC
High
1~32
0x10
0x00
0x25
0x00
0x02
0x04
0.0~16.8 or
0.0~33.6, 4 bytes
stored in float
point type
Calculated based on
the first 11 bytes
3)
Return Instruction Format
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x10
0x00
0x24
0x00
0x01
Calculated based on the first 6
bytes
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High