Programming Manual MSO/UPO2000 Series
84 / 156
Instruments.uni-trend.com
:SBUS:RS232:SOURce?
Query returns CHANnel1.
:SBUS:RS232:POLarity
Command format
:
:SBUS:RS232:POLarity { POSitive | NEGative }
:SBUS:RS232:POLarity?
Functional description
:
This command is used to set RS232 bus decoding polarity of the oscilloscope, which includes POSitive and
NEGative.
Return format
:
Query returns { POSitive | NEGative }.
For example
:
:SBUS:RS232:POLarity POSitive
Set RS232 bus decoding polarity to POSitive.
:SBUS:RS232:POLarity?
Query returns POSitive.
:SBUS:RS232:PARity
Command format
:
:SBUS:RS232:PARity {EVEN | ODD | NONE}
:SBUS:RS232:PARity?
Functional description
:
This command is used to set RS232 bus parity of the oscilloscope.
Return format
:
Query returns {EVEN | ODD | NONE}.
For example
:
:SBUS:RS232:PARity ODD
Set RS232 bus parity to ODD.
:SBUS:RS232:PARity?
Query returns 6.
:SBUS:RS232:DATA:BIT
Command format
:
:SBUS:RS232:DATA:BIT {5 | 6 | 7 | 8 }
:SBUS:RS232:DATA:BIT?
Functional description
:
This command is used to set RS232 bus data bit of the oscilloscope.
Return format
:
Query returns {5 | 6 | 7 | 8 }.
For example
:
:SBUS:RS232:DATA:BIT 6
Set RS232 data bit to 6.
:SBUS:RS232:DATA:BIT?
Query returns 6