122 Appendix
WAGO-I/O-SYSTEM
750
750-657 IO-Link Master
Manual
Version 1.0.2, valid from FW/HW-Version 02/01
11.3.5
IOL-M Directory Record
Do not confuse the "IOL-M Directory" record with "IOL-M Basic/Port
Configuration"!
Do not confuse the "IOL-M directory" record with the data of the "OL-M Basic
configuration" and "IOL-M Port configuration" records.
The "IOL-M directory" only contains information about the IO-Link master itself
and is read only.
Table 117: IOL-M Directory Record
Parameter
Data type
Access Description
IO-Link Version
UNSIGNED8
ro
Supported IO-Link revision of the master
IO-Link Profile Version UNSIGNED8
ro
IO-Link profile
IO-Link Feature Support UNSIGNED32 ro
Bit fields that display features
Number of Ports
UNSIGNED8
ro
Number of IO-Link ports available
REF Port Config
UNSIGNED8
ro
Index to port configuration
REF IO Mapping
UNSIGNED8
ro
Index to I/O mapping
REF iPar Directory
UNSIGNED8
ro
Index to iPar director
REF IOL M
UNSIGNED8
ro
Index to IOL-M parameters
Number of CAP
UNSIGNED8
ro
Number of client access points
11.3.5.1 IO-Link Version
Table 118: Master configuration, “IO-Link Version“
Name
Access
Value
Description
IO-Link-Version ro
0x10:
IO-Link
1.0
0x11: IO-Link 1.1
Supported IO-Link revision of master
11.3.5.2 IO-Link Profile Version
Table 119: Master configuration, “IO-Link Profile Version“
Name
Access
Value
Description
IO-Link Profile Version
ro
0x00
IO-Link profile
11.3.5.3 IO-Link Feature Support
Table 120: Master configuration, “IO-Link Feature Support”
Name
Access
Value
Description
IO-Link Feature Support
ro
0x00000000
IO-Link feature support