6-65
TI71M01D06-01EN 3rd Edition: 2012.12.01
Make sure that the signals observe the following sequence when using the M function.
When the OUT_M_EN signal turns ON, the table number currently being executed is output
to OUT_0_CODE [5..0] as a binary value. The M function is terminated when IN_M_ANS
turns ON while OUT_M_EN is being output.
Signal Timing of the M Function
In the case of non-parallel operation
* If IN_M_ANS is not assigned, the M function is automatically terminated after OUT_M_EN turns ON for
10msec.
Signal Timing of the Parallel M Function In the case of parallel operation
* If IN_N_ANS is not assigned, the M function is automatically terminated after OUT_M_EN turns ON for
10msec.
Operation of the M function at error occurrence
If [Stop the M function at error] is set to [Valid] in [System register 2] of the #parameter window,
the execution of the M function stops when an error occurs. If it is set to [Invalid], the
execution of the M function continues even if an error occurs.
TIP
Undetermined
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
Undetermined
Undetermined
5msec or more
M function terminated
The table number currently being
executed is output.
5msec or more
IN_START
OUT_MODE_EXE
IN_M_ANS
OUT_O_CODE
[5..0]
OUT_M_EN
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
Undetermined
5msec or more
5msec or more
M function terminated
The table number currently being
executed is output.
* Whichever occurs later
IN_START
OUT_MODE_EXE
IN_M_ANS
OUT_O_CODE
[5..0]
OUT_M_EN