TPMC533 User Manual Issue 1.0.1
Page 25 of 107
3.2.1.2.4
ADC Mode Registers (0x048, 0x08C, 0x0D0 and 0x114)
For each ADC (for all eight ADC Channels of each ADC) it is configurable whether to use the ADC
Sequencer to periodically write AD samples into Host RAM or whether AD samples are only read manually
from ADC Data Registers.
Bit
Symbol
Description
Access
Reset
Value
31:1
-
Reserved
-
-
0
ADCx_MODE
ADC Operating Mode
0: Manual Mode
1: Sequencer Mode
This bit sets the general ADC Operating Mode.
In Manual Mode, analog sampling is requested by software
commands (there is no periodic conversion rate).
In Sequencer Mode, analog inputs are sampling periodically
at a configurable conversion rate.
R/W
0
Table 3-20: ADC Mode Register
Note that all eight channels of an ADC are always operating in the same Operating Mode.