S e n d c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m
-SM-46
Cisco Nexus 3000 Series NX-OS System Management Command Reference
OL-29557-04
Chapter System Management Commands
destination-profile (Call Home)
destination-profile (Call Home)
To create a user-defined destination profile, modify a predefined or user-defined destination profile, or
configure the message format for that new destination profile, use the
destination-profile
command. To
remove the destination profile, use the
no
form of this command.
destination-profile
{
CiscoTAC-1
| {{
full-txt-destination
|
short-txt-destination
}{
message-level
level
|
message-size
size
}}} {
alert-group
alert
|
email-addr
email-address
|
http
url
|
transport-method
{
|
http
}}
destination-profile
profile-name
[
alert-group
alert
|
email-addr
email-address
|
format
{
XML
|
full-txt
|
short-txt
} |
http
url
|
message-level
level
|
message-size
size
|
transport-method
{
|
http
}]
no destination-profile
Syntax Description
CiscoTAC-1
Configures a destination profile for Extensible Markup Language (XML)
messages.
full-txt-destination
Configures a destination profile for plain text messages.
short-txt-destination
Configures a destination profile for short text message.
message-level
level
Specifies the Call Home message severity level. The range is from 0 to 9,
with 0 being the lowest urgency, and 9 the highest urgency.
message-size
size
Specifies the maximum message size. The range is as follows:
•
full-txt-destination
—From 0 to 5000000, and the default is 2500000.
•
short-txt-destination
—From 0 to 100000, and the default is 4000.
•
CiscoTAC-1
—5000000, which is not changeable.
alert-group
alert
Associates one or more alert groups with a destination profile. The
alert
group can be one of the following:
•
All
—All alert groups
•
Cisco-TAC
—Cisco TAC events
•
Configuration
—Configuration events
•
Diagnostic
—Diagnostic events
•
EEM
—EEM events
•
Environmental
—Power, fan, and temperature-related events
•
Inventory
—Inventory status events
•
License
—Licensing events
•
Linecard-Hardware
—Linecard-related events
•
Supervisor-Hardware
—Supervisor-related events
•
Syslog-group-port
—Syslog message events filed by the port manager
•
System
—Software-related events
•
Test
—User-generated test events
email-addr