DX-1S Digital PABX - Programming Manual
1-1
1
INTRODUCTION
This manual provides general description and procedures of system programming for DX-1S Digital
PABX System with Version 6.19 System Software and MFC-1S Console with Version 4.72 Software
installed. Since the operation and programming will be different in different version software, the
information in this manual will not be correct if the system is installed with other version system software.
The system should be programmed after the hardware installation. All the system parameters and
programming data is input through MFC-1S Console, so that it must set up the MFC-1S Console at first
before the system programming. The following table shows the procedure to program the whole system
after hardware installation:
Step
Procedure
1
Setup the console in MFC-1S Console Setup Mode.
2
Program the system in MFC-1S Programming Mode.
3
Print out the programming data for checking and filing.
4
Perform functional test to verify the programming data.
Table 1-1 PROCEDURE TO PROGRAM THE SYSTEM
After programming, the system can be customized to meet different requirements of the customers.
For the system, which is upgraded from older version system software, the user should refer to the
Updated section for the procedures to upgrade the system software and re-programming the system
programming data.
The Programming Manual is divided into the following sections:
•
Introduction
•
Important Notes
•
Basic Operation in Programming Mode
•
Programming Operation
•
System Programming Details
•
Summary
•
Programming Record
IMPORTANT NOTE:
The programming data and SMDR data will be lost when the system software is upgraded from
previous versions (Version 1.XX to 3.XX) to Version 4.XX. It is advised to back up the hardcopy
of the programming data and SMDR data before upgrading the system software. The operator
should re-program the system after upgrading the software. The following procedures are
recommended to follow for system upgrading to Version 4.XX.
1.
Print hard copy of existing programming data.
2.
Print / dump all SMDR data.
3.
Prepare new values of programming items 41, 42, 65, 66, 70, 71, 72, 89 and 112 for
definition are re-defined. For details, please refer to Programming Manual.
4.
Re-arrange speed dialing memory number if more than 300 are used (new
numbering are from 0 ~ 299). For details, please refer to Programming Manual.
5.
Upgrade software FLASH PROM.
6.
Power up the system.
7.
At programming mode, execute command “8*2168” to reset all programming data
to default value. For details, please refer to Programming Manual.
8.
At diagnostic mode, execute command “3057*7150” to reset all SMDR records to
null and reformat SMDR records to new format. For details, please refer to
Maintenance Manual.
9.
Re-program the system completely.
10.