5.7.20 PROGRAMMING ITEM 119 : NETWORK HUNTING GROUP
Two or more DX-1S Systems can be tied up with Loop Start Networking feature to form a larger capacity
system. The intercom calls and trunk calls of each system can transfer to other systems in the network.
This item is programmed which extension group is used as network hunting group and the first digit of
the directory number of other DX-1S System which the network hunting group connected to. For
example, the directory number of the first system is programmed to be 1XXX and the second system is
programmed to be 2XXX. These two systems are tied up with network trunks and network extensions.
In this case, the directory access code of the extension hunting groups which are used as network hunting
group in the first system should be programmed to be 2. The directory access code of the networking
hunting group in the second system should be programmed to be 1. After the programming, the first
system will transfer all the calls to the second system through the networking hunting group when the
directory number of the called extension is 2XXX. The second system will also transfer all the calls to
the first system through the network hunting group when the directory number of the called extension is
1XXX. If the directory access code of the extension group is programmed to be 255 in this item, it will
tell the system that the extension hunting group is a normal hunting group, but not a network hunting
group.
Command
3 * 119 * Index1 * Value <Enter> or
3 * 119 * Index1 * Value * Index2 <Enter>
where Index1 = 1 ~ 5 : Directory Access Code
Index2 = 1 ~ 5 : Directory Access Code <Optional>
Value = 240 ~ 254 : extension hunting group
Value = 255 : local intercom call
Default Value
Directory Access Code 1 = 255 (local intercom call)
Directory Access Code 2 = 255 (local intercom call)
Directory Access Code 3 = 255 (local intercom call)
Directory Access Code 4 = 255 (local intercom call)
Directory Access Code 5 = 255 (local intercom call)
5.7.21 PROGRAMMING ITEM 120 : TONE SIGNAL GAIN / DISA PARAMETERS
This is to program the tone signal level. If the value is larger, the signal level will be higher.
Command
3 * 120 * Index1 * Value <Enter> or
3 * 120 * Index1 * Value * Index2 <Enter>
where Index1 = 0 ~ 16, 23 ~ 29: Tone number
= 17: Fixed / Variable DISA parameters
= 18: DISA voice playback gain
= 19: DISA voice record / DTMF receiver loss
= 20 ~ 22 echo loss parameters
Index2 = 0 ~ 16, 23 ~ 29: Tone number <Optional>
= 17: Fixed / Variable DISA parameters <Optional>
= 18: DISA voice playback gain <Optional>
= 19: DISA voice record / DTMF receiver loss <Optional>
= 20 ~ 22 echo loss parameters <Optional>
Value = 1 ~ 255 : Gain (relative) / parameters
1 = Variable DISA parameter, other value = fixed DISA parameter (for index1 = 17)
Note : For every gain unit offset from the default value, 0.1 dB is changed.