DX-1S Digital PABX - Programming Manual
5-7
5.1.29 PROGRAMMING ITEM 28 : TRUNK DIALING TIMEOUT A
Trunk Dialing Timeout A is the duration that the system will wait to receive the dialing digit from
extension to send to trunk line for outgoing call dialing. The system will assume the dialing process is
finished if no dialing digit is received within Trunk Dialing Timeout A. The Trunk Dialing Timeout A is
only applicable to the first few digits which is defined in Programming Item 30 : No. of Digits Using
Timeout A.
Command
3 * 28 * Value <Enter>
where Value = 1 ~ 255 (seconds)
Example
If the data is set as follows:
Trunk Dialing Timeout A = 25
Trunk Dialing Timeout B = 5
No. of Digits using Timeout A = 2
Then the timeout of waiting for outgoing digits will be as follows:
Digit 1 ~ 2 : 25 seconds
Digit 3 ~ 24 : 5 seconds
Default Value
Default = 25 (seconds)
Related Topic
1.
Programming Item 29 - Trunk Dialing Timeout B
2.
Programming Item 30 - No. of Digits Using Timeout A
Figure 5-1 TRUNK DIALING TIMEOUT A & B DIAGRAM
5.1.30 PROGRAMMING ITEM 29 : TRUNK DIALING TIMEOUT B
After the first few digit which is defined in Programming Item 30 : No. of Digits Using Timeout A is sent,
the system will wait for the duration of Trunk Dialing Timeout B value to receive the following dialing
digits after from extension to send to trunk line for outgoing call dialing. The system will assume the
dialing process is finished if no dialing digit is received within Trunk Dialing Timeout B. The Trunk
Dialing Timeout B is only applicable to the following digits after the digits which is defined in
Programming Item 30 : No. of Digits Using Timeout A.
Command
3 * 29 * Value <Enter>
where Value = 1 ~ 255 (seconds)
Default Value
Default = 5 (seconds)
Related Topic
1.
Programming Item 28 - Trunk Dialing Timeout A
2.
Programming Item 30 - No. of Digits Using Timeout A