Memory Map/Register Definition
MCF52110 ColdFire® Integrated Microcontroller Reference Manual, Rev. 1
Freescale Semiconductor
11-11
Preliminary
11.2.1.9
RTC Days Counter Register (DAYS)
The real-time clock days counter register (DAYS) is used to program the day for the TOD clock. When the
HOUR field of the HOURMIN register rolls over from 23 to 00, the day counter increments. It can be read
or written at any time. After a write, the time changes to the new value. This register cannot be reset
because the real-time clock is always enabled at reset. Only 16-bit accesses to this register are allowed.
Figure 11-10. RTC Days Counter Register (DAYS)
IPSBAR
Offset: 0x03E0 (DAYS)
Access: User read/write
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
R
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
DAYS
W
Reset
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
Table 11-10. DAYS Field Descriptions
Field
Description
31–16
Reserved, should be cleared.
15–0
DAYS
Day Setting. This field indicates the current day count, and can be set to any value between 0 and 65535.