Debug Module
MCF52110 ColdFire® Integrated Microcontroller Reference Manual, Rev. 1
Freescale Semiconductor
27-35
Preliminary
Command Sequence:
Figure 27-35.
SYNC
_
PC
Command Sequence
Operand Data:
None
Result Data:
Command complete status (0xFFFF) is returned when the register write is
complete.
27.5.3.3.10
Read Control Register (
RCREG
)
Read the selected control register and return the 32-bit result. Accesses to the processor/memory control
registers are always 32 bits wide, regardless of register width. The second and third words of the command
form a 32-bit address, which the debug module uses to generate a special bus cycle to access the specified
control register. The 12-bit Rc field is the same the processor’s MOVEC instruction uses.
Command/Result Formats:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0x0
0x0
0x0
0x1
Figure 27-34.
SYNC
_
PC
Command Format
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Command
0x2
0x9
0x8
0x0
0x0
0x0
0x0
0x0
0x0
Rc
Result
D[31:16]
D[15:0]
Figure 27-36.
RCREG
Command/Result Formats
SYNC_PC
???
NEXT CMD
CMD COMPLETE