78
■
Arbitrary point radiation coordinate and time: PRD
Sets arbitrary point radiation X/Y coordinates, radiation time and laser power correction ratio.
Setting of arbitrary point radiation coordinate and time
STX
PRD
S
[Point radiation condition No.] [Start line]
[Radiation time] [Laser power correction]
[X position] [Y position] [• • •] [X position] [Y position]
15+16n-byte
(Check sum)
Delimiter
Setting of radiation time, and laser power correction only
STX
PRD
S
[Point radiation condition No.] [Line No.]
[Radiation time] [Laser power correction]
15-byte
(Check sum)
Delimiter
Delete of arbitrary point radiation condition
STX
PRD
S
[Point radiation condition No.] [Start line] [End line]
8-byte
(Check sum)
Delimiter
Readout request of arbitrary point radiation coordinate and time
STX
PRD
R
[Point radiation condition No.] [Line No.]
5-byte
(Check sum)
Delimiter
Readout data of arbitrary point radiation coordinate and time
STX
PRD
A
[Point radiation condition No.] [Line No.] [Radiation time]
[Laser power correction] [X position] [Y position]
Max. 31-byte
(Check sum)
Delimiter
When there is no setting data in the selected line, [Radiation time], [Laser power correction], [X position] and [Y position]
fields are not existed.
Name
Data length
[byte]
Description
Remarks
Point radiation
condition No.
2
“00”–“15”
Line No.
3
“000”–“049”
Start line
3
“000”–“049”
End line
3
Radiation time
7
“00000.1”–“99999.9” [ms]
Laser power
correction
3
“000”–“999” [%]
Indicates the correction value for
laser power specified at the laser
setting.
X position
8
Model type*
Setting range [mm]
LP-Sxx0(W)
“-045.000”–“+045.000”
LP-Sxx5(W)
“-080.000”–“+080.000”
LP-Sxx2
“-027.500”–“+027.500”
LP-Mxx0/LP-Zxx0 “-060.000”–“+060.000”
LP-Mxx5
“-110.000”–“+110.000”
LP-Mxx6/LP-Zxx6 “-165.000”–“+165.000”
Y position
8
* For the detail of the model type, refer to “Target laser marker” (P.4).
Reference
•
The coordinate numbers that can be set or read out at once are max. 50 points.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...