196
46.2
ONT Firmware Custom Update
To update firmware of a specified ONT, you need to create a corresponding task and specify the ONT ID
and the firmware file name. There are two types of ONT firmware update tasks: single try or multiple tries.
To create a single try update task, use the
update ont
command and specify the ONT ID and the file name
of the firmware:
LTP-8X# update ont 0/0 ntp-rg-r3.24.1.854.fw.bin
Task for updated successfully created. ONT firmware will be updated in 20 minutes or more
As a result, the single try update task will be created for the ONT having the specified serial number. This
method is used to update the ONTs, which are in the OLT channel at the time of update. The task will end
with an error for the ONTs, which are not connected.
To create a multiple tries update task, use a scheduler. This method is generally used to update the ONTs,
which are not in the OLT channel at the time of the update. The tasks you create in the scheduler will be
executed as soon as the corresponding ONT connects to the channel. To create, delete, or view tasks in the
scheduler, use the
schedule ont
command. To create an ONT firmware update task, use the
schedule ont
update
command and specify the ONT ID and the firmware update file:
LTP-8X# schedule ont update 0/0 ntp-rg-r3.24.1.854.fw.bin
Task created for [ONT0/0]
To view scheduled tasks, use the
schedule ont update firmware show
command:
LTP-8X# show schedule ont update Existing tasks (1):
##
Serial
Ch/ Id
Operation
Status
Tries remained
0
---
0/ 0
ont_update
scheduled
5
You can delete some of the created tasks by using the
no schedule ont update
command and specifying
the ONTs ID:
LTP-8X(pon)> no schedule ont update 0/0
Task deleted for [ONT0/0]
To clear the scheduler, use the
clear schedule ont update
command:
LTP-8X# clear schedule ont update
All tasks cleared
The tasks created in the scheduler will continue running until the update completes successfully or the
number of tries is reached (the "tries remained" parameter).
Summary of Contents for LTP-4X
Page 11: ...11 Part I General ...
Page 29: ...29 Part II Getting Started with the Terminal ...
Page 37: ...37 Part III Configuring the Terminal ...
Page 98: ...98 Part IV ONT Configuration ...
Page 174: ...174 Part V Terminal Monitoring ...
Page 189: ...189 Part VI Terminal Maintenance ...
Page 191: ...191 Step 2 Remove the module from the slot Fig 43 4 Removing SFP Transceivers ...