RS-485 Remote Control Protocol
Page 6-16
Reference Guide: SM6610, SM6615, SM6620 and SM6625 Satellite Modulators
ST.RE.E10152.2
6.5 Get
Status
The start field for this message is ACK.
Table 6.17: Get Status
Size
Type
0x77
2
Value
Protocol Version
0x00 - 0xFF
(See Section 6.8 Protocol Version)
2
Bit 0
1
0..5 - Reserved
Ignore value
6 - Modulation
Off
On
Modulator
Status
7 - Carrier On/Off
Off
On
2
Symbol clock offset (ppm)
Signed integer value, MSB first
4
Temperature
(
°
C) Signed
byte
2
Bit 0
1
0 - Reserved
Ignore value
1 - Alarm 1
OK
Set
2 - Alarm 2
OK
Set
3 - Alarm 3
OK
Set
4 - Alarm 4
OK
Set
5 - Fail
OK
Set
Alarm
Status
6..7 - Reserved
Ignore value
2
Operation Status
0x00 - Configuring
0x01 - Standby
0x02 - Active, carrier On
2
6.6
Save Current Configuration
The start field for this message is ACK if OK is indicated, otherwise the
start field is NAK.
Table 6.18: Save Current Configuration
Size
Type
0x80
2
Value
Operation Success
0x00 - Error
0x01 - OK
0x0F - Invalid Parameter
2