Maintenance 9. Troubleshooting
RC90 (EPSON RC+ 7.0) Rev.8
161
No.
Message
Remedy
Note 1
Note 2
3335
Call cannot be used in parallel
processing.
Call cannot be used in parallel
processing. Correct the program and
rebuild the project.
3336
Variable was redefined.
Correct the data type of the variable and
rebuild the project.
3400
Dialog ID was not specified.
Dialog ID is not specified in RunDialog
statement. Refer to
SPEL+ Language
Reference
“
RunDialog Statement
” and
specify a dialog ID.
3401
Main function name was not specified.
Name of the main function to execute is
not specified in StartMain statement.
Specify a main function name (main to
main63).
3402
Vision object name was not specified.
Vision object name is not specified in
VLoadModel, VSaveModel,
VShowModel, VTeach, and VTrain
statements. Specify an object name.
3403
Recover mode ID was not specified.
Recover mode is not specified in
Recover statement or Recover function.
Refer to
SPEL+ Language Reference
“
Recover Statement
” and specify a
proper mode.
3404
Trap condition was not specified.
Trap number or trap event is not
specified in Trap statement. Refer to
SPEL+ Language Reference
“
Trap
Statement
” and specify a proper trap
number or event.
3405
DialogResult was not specified.
DialogResult property setting value is
not specified in GSet statement. Refer
to
GUI Builder 7.0
“
DialogResult
Property
” and specify a proper setting
value.
3406
MsgBox_Type was not specified.
Display type is not specified in MsgBox
statement. Refer to
SPEL+ Language
Reference
“
MsgBox Statement
” and
specify a proper setting value.
3407
Byte type array variable was not
specified.
Byte type array variable is not specified
for send or receive data in
FbusIO_SendMsg statement.
Send/receive data must be specified by
Byte type array.
3408
Single array variable was not
specified.
The number of dimensions is not proper
in the command where single array
variable is only available. Correct the
number of dimensions.
3409
Point list is not specified.
Pixel coordinate or robot coordinate is
not specified as a continuous point data
in VxCalib statement. Specify a
continuous point data in the following
format: P (start : end)
3410
Code type is not specified.
CodeType property setting value is not
specified in VSet statement. Refer to
Vision Guide 7.0 Properties & Results
Reference
“
CodeType Property
” and
specify a proper setting value.
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...
Page 17: ...Safety This section contains information for safety of the Robot System ...
Page 18: ......
Page 24: ......
Page 28: ...Setup Operation 1 Specifications 12 RC90 EPSON RC 7 0 Rev 8 1 3 Outer Dimensions Unit mm ...
Page 95: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 96: ......