MAX32600 User’s Guide
Analog Front End
8.3 ADC
Set by hardware when an ADC FIFO underflow condition occurs (empty FIFO is read).
Write 1 to clear.
ADC_INTR.fifo_of
Field
Bits
Default
Access
Description
fifo_of
12
0
W1C
ADC FIFO Overflow Interrupt Flag
Set by hardware when an ADC FIFO overflow condition occurs (full FIFO is written).
Write 1 to clear.
ADC_INTR.fifo_tf
Field
Bits
Default
Access
Description
fifo_tf
13
0
W1C
ADC FIFO Three-Quarters Full Interrupt Flag
Set by hardware when the level of the ADC FIFO reaches the three-quarter full point.
Write 1 to clear.
ADC_INTR.fifo_hf
Field
Bits
Default
Access
Description
fifo_hf
14
0
W1C
ADC FIFO Half Full Interrupt Flag
Set by hardware when the ADC FIFO reaches the half full point.
Write 1 to clear.
Rev.1.3 April 2015
Maxim Integrated
Page 439